±±¾©ÐÂмÒÔ°µØÔ´ÈȱÃÏîÄ¿
1¡¢ÏîÄ¿¸Å¿ö
£¨1£©ÐÞ½¨¸Å¿ö£º
±±¾©ÐÂмÒÔ°µØÔ´ÈȱÃÏîĿλÓÚ±±¾©ÊУ¬ÐÞ½¨Ãæ»ý2400©O¡£±¾ÏîÄ¿×îºó½ÓÄÉÖÐÑë¿Õµ÷·ç»úÅ̹Üϵͳ¡£±¾ÏîÄ¿µÍÎÂÀäÈÈÔ´½ÓÄɵØÔ´ÈȱÃϵͳ¡£
£¨2£©ÊÒÍâÉè¼Æ²ÎÊý£º
¶¬¼¾ÊÒÍâ¿ÕÆøµ÷ÀíÅÌËãÎÂ¶È |
-9.9¡æ |
¶¬¼¾ÊÒÍâ͸·çÅÌËãÎÂ¶È |
-3.6¡æ |
¶¬¼¾¹©Å¯ÅÌËãÎÂ¶È |
-7.6¡æ |
¶¬¼¾²ÉůÌìÊý |
123Ìì |
ÏÄÈÕ¿ÕÆøµ÷Àí¸ÉÇòÎÂ¶È |
33.5¡æ |
ÏÄÈÕ͸·çÅÌËãÎÂ¶È |
26.4¡æ |
ÏÄÈÕ¿ÕÆøµ÷ÀíʪÇòÎÂ¶È |
29.7¡æ |
ÏÄÈÕÖÆÀäÌìÊý |
90Ìì |
2¡¢ÀäÈȸººÉÅÌËã
ÏîÄ¿ |
µ¥Î» |
ÊýÖµ |
ÅÌË㹫ʽ/±¸×¢ËµÃ÷ |
|
Àä |
ÐÞ½¨Ãæ»ý (S) |
©O |
2400 |
|
Éè¼ÆÈȸººÉÖ¸±ê£¨q£© |
W/©O |
150 |
|
|
×î¾ÞϸʱÈȸººÉ£¨Q£© |
KW |
360 |
Q=q×S÷1000 |
|
Éè¼ÆÀ为ºÉÖ¸±ê£¨q£© |
W/©O |
150 |
|
|
×î¾ÞϸʱÀ为ºÉ£¨Q£© |
KW |
360 |
Q=q×S÷1000 |
3¡¢Èȱûú×éÑ¡ÐÍ
|
µØÔ´Èȱûú×é |
Èȱûú×éÐͺŠ|
SSDR-190BHP |
Èȱûú×éÊýÄ¿ |
2̨ |
ÖÆÀäÁ¿ |
182.4 KW |
ÖÆÀ书ÂÊ |
41.4 KW |
ÖÆÈÈÁ¿ |
191.8 KW |
ÖÆÈȹ¦ÂÊ |
53.4 KW |
µçѹ |
380V |
4¡¢»ú·¿±ÃÀàÑ¡ÐÍ
ÏîÄ¿ |
µ¥Î» |
ÊýÖµ |
±¸×¢ |
ϵͳ²àÑ»·±ÃÑ¡ÐÍ |
̨ |
3 |
Q=46.7T/H£¬H=28M£¬N=7.5KW£¬Á½ÓÃÒ»±¸ |
µØÔ´²àÑ»·±ÃÑ¡ÐÍ |
̨ |
3 |
Q=50T/H£¬H=32M£¬N=7.5KW£¬Á½ÓÃÒ»±¸ |
ϵͳ²¹Ë®±ÃÑ¡ÐÍ |
̨ |
2 |
Q=2.5T/H£¬H=32M£¬N=1.1KW£¬Ò»ÓÃÒ»±¸ |
µØÔ´²¹Ë®±ÃÑ¡ÐÍ |
̨ |
2 |
Q=2.5T/H£¬H=32M£¬N=1.1KW£¬Ò»ÓÃÒ»±¸ |
5¡¢Ï½µµÍ÷³Ìͼ
6¡¢¸ßЧµØÔ´¾®ÐÎò
1£©µØÔ´Èȱûú×鶬¼¾¹©Å¯¹©»ØˮζÈΪ45/40¡æ£¬µØÂñ¹Ü²àÊÕ֧ˮζÈ10/5¡æ£»
µØÔ´Èȱûú×éÖÆÀ乩»ØˮζÈΪ7/12¡æ£¬µØÂñ¹Ü²àÊÕ֧ˮζÈ30/35¡æ£»
2£©±¾ÏîÄ¿Éè¼ÆµØÂñ¹Ü»»ÈÈÆ÷×ܳ¤¶ÈΪ4500m£¬µØÔ´ÈȱõØÂñ¹Ü»»ÈÈÆ÷²¿·Ö¹²15¸ö×ê¿×£¬×ê¿×¼äµÄ¼ä¾àÄϱ±ÏòΪ6Ã×£¬¹¤¾ßÏò6Ã×£¬×ê¿×ÄÚÉèÖøßЧÌ×¹ÜʽµØÂñ¹Ü»»ÈÈÆ÷£¬»»ÈÈÆ÷ÏÖʵ³¤¶ÈΪ300Ãס£